Stuffed and wired main panel.  All of the wiring to the heater elements is 12g high temp wire.  I used 40A relays, each element draws 10 to 11.2 Amps.  If you elect to use the FOTEK SSR's make sure they are not the knock offs.  Apparently there are some very inferior chinese replicas that have a tendency to burn out or lock turned on.  In use the heat sinks hardly get warm.  My original plan was to run the unit with the door open for cooling.  This is not needed.